Initialization
WARNING: Keep objects and body parts clear of the glass panel when carrying out the initialization procedure. During the initialization procedure, the glass panel closes with high force and cannot detect objects in its path. Failure to follow this instruction may result in serious personal injury.
NOTE: A new roof opening panel motor must be initialized after installation. It will only move toward the vent position until initialized.
NOTE: The roof opening panel motor initialization procedure must be done when repairs are carried out on any part of the roof opening panel system, including: any time the roof opening panel motor has been removed from the roof opening panel assembly, a new roof opening panel motor has been installed or when a new roof opening panel assembly has been installed.
NOTE: All passenger doors must remain closed for this procedure and the sunroof must start out in the fully closed position.
Open the driver door and position the ignition switch ON, engine OFF.NOTE: Perform steps 3 - 5 within 5 seconds.
Press the vent button (the roof opening panel glass moves to the full vent position).NOTE: The driver door must remain open for the rest of the procedure.
Open the driver door.NOTE: Do not release the vent button until the roof opening panel glass is fully closed.
Press and hold the vent button while the roof opening panel glass cycles fully open and finally to the fully closed position. Release the vent button.Note: Depending on your vehicle option package, the controls may look different from what you see here.