Other information:
B0072:11, B0072:12, B0072:13 and B0072:1A
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM continuously monitors the passenger seatbelt anchor pretensioner circuits for the following faults:
Resistance out of range
Unexpected voltage
Short to ground
Faulted passenger seatbelt anchor pretens..
Special Tool(s) /
General Equipment
Flat Headed Screw Driver
Removal
Open the fuel filler door.
Press the tab to release the fuel filler door spring from the fuel filler door assembly.
Use the General Equipment: Flat Headed Screw Driver
Installation
To install, reverse the removal procedure.
..